{"id":8970,"date":"2026-01-30T14:18:50","date_gmt":"2026-01-30T11:18:50","guid":{"rendered":"https:\/\/sunucun.com.tr\/bilgi\/?post_type=dt_articles&#038;p=8970"},"modified":"2026-11-12T18:51:14","modified_gmt":"2026-11-12T15:51:14","slug":"datacenter-switch","status":"publish","type":"post","link":"https:\/\/sunucun.com.tr\/blog\/datacenter-switch\/","title":{"rendered":"Datacenter Switch Nedir? ToR, EoR ve Spine-Leaf Mimarisi"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>K\u0131sa cevap:<\/strong> Datacenter switch, veri merkezindeki sunucular\u0131, depolama sistemlerini ve di\u011fer a\u011f cihazlar\u0131n\u0131 birbirine ve internete ba\u011flayan, y\u00fcksek port yo\u011funluklu ve d\u00fc\u015f\u00fck gecikmeli a\u011f anahtar\u0131d\u0131r. En yayg\u0131n t\u00fcr\u00fc <strong>ToR (Top of Rack) switch<\/strong>&#8216;tir: her kabinin en \u00fcst\u00fcne konur ve o kabindeki sunucular do\u011frudan ona ba\u011flan\u0131r. ToR switch&#8217;ler de g\u00fcn\u00fcm\u00fcz veri merkezlerinde \u00e7o\u011funlukla <strong>spine-leaf<\/strong> mimarisiyle birbirine ba\u011flan\u0131r.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/sunucun.com.tr\/blog\/wp-content\/uploads\/2026\/01\/text-10-temel-switch.jpg\" alt=\"Veri merkezi kabininde raf \u00fcst\u00fc (ToR) switch ve sunucu kablolamas\u0131\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Datacenter Switch&#8217;i Ofis Switch&#8217;inden Ay\u0131ran Nedir?<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Port h\u0131z\u0131:<\/strong> Sunucu ba\u011flant\u0131lar\u0131 genellikle 10, 25 veya 100 Gbit\/s, switch&#8217;ler aras\u0131 ba\u011flant\u0131lar (uplink) 100 veya 400 Gbit\/s&#8217;dir. Ofis switch&#8217;lerinde ise 1 Gbit\/s yayg\u0131nd\u0131r.<\/li>\n<li><strong>D\u00fc\u015f\u00fck gecikme ve y\u00fcksek kapasite:<\/strong> T\u00fcm portlar ayn\u0131 anda tam h\u0131zda \u00e7al\u0131\u015fabilecek \u015fekilde tasarlan\u0131r.<\/li>\n<li><strong>Yedeklilik:<\/strong> \u00c7ift g\u00fc\u00e7 kayna\u011f\u0131, de\u011fi\u015ftirilebilir fanlar; iki switch&#8217;e ayn\u0131 anda ba\u011flanan sunucularla (MLAG gibi y\u00f6ntemler) tek switch ar\u0131zas\u0131nda ba\u011flant\u0131 kopmaz.<\/li>\n<li><strong>Kabin uyumlu so\u011futma:<\/strong> So\u011fuk\/s\u0131cak koridor d\u00fczenine uygun \u00f6nden arkaya (veya arkadan \u00f6ne) hava ak\u0131\u015f\u0131.<\/li>\n<li><strong>Ba\u011flant\u0131 mod\u00fclleri:<\/strong> Portlar SFP28, QSFP28, QSFP-DD gibi mod\u00fcl yuvalar\u0131d\u0131r; fiber veya bak\u0131r mod\u00fcl tak\u0131larak kullan\u0131l\u0131r. Ayr\u0131nt\u0131lar: <a href=\"https:\/\/sunucun.com.tr\/blog\/sfp-cesitleri-nelerdir-ne-icin-kullanilir\/\">SFP \u00e7e\u015fitleri<\/a> ve <a href=\"https:\/\/sunucun.com.tr\/blog\/fiber-kablo-cesitleri-nelerdir-ne-icin-kullanilir\/\">fiber kablo \u00e7e\u015fitleri<\/a>.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ToR, EoR ve MoR: Switch Nereye Konur?<\/h2>\n\n\n\n<div class=\"snc-table-wrap\"><table>\n<thead><tr><th>Yerle\u015fim<\/th><th>Nas\u0131l \u00e7al\u0131\u015f\u0131r?<\/th><th>Avantaj\u0131<\/th><th>Dezavantaj\u0131<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>ToR (Top of Rack)<\/td><td>Her kabinin en \u00fcst\u00fcnde bir (genellikle yedekli iki) switch; kabindeki sunucular k\u0131sa kablolarla ona ba\u011flan\u0131r<\/td><td>K\u0131sa kablolar, d\u00fczenli kablolama, kabin kabin b\u00fcy\u00fcme<\/td><td>Kabin ba\u015f\u0131na switch, daha fazla cihaz y\u00f6netimi<\/td><\/tr>\n<tr><td>EoR (End of Row)<\/td><td>Kabin s\u0131ras\u0131n\u0131n sonundaki kabinde b\u00fcy\u00fck switch&#8217;ler; s\u0131radaki t\u00fcm sunucular oraya kablolan\u0131r<\/td><td>Daha az switch, merkez\u00ee y\u00f6netim<\/td><td>Uzun ve kalabal\u0131k kablo yollar\u0131<\/td><\/tr>\n<tr><td>MoR (Middle of Row)<\/td><td>EoR ile ayn\u0131 mant\u0131k, switch kabini s\u0131ran\u0131n ortas\u0131nda<\/td><td>EoR&#8217;a g\u00f6re daha k\u0131sa en uzun kablo<\/td><td>Yine yo\u011fun yatay kablolama<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Sunucu say\u0131s\u0131n\u0131n ve h\u0131zlar\u0131n artt\u0131\u011f\u0131 modern veri merkezlerinde en yayg\u0131n yakla\u015f\u0131m ToR&#8217;dur. &#8220;ToR switch nedir&#8221; sorusunun k\u0131sa cevab\u0131: kabinin tepesindeki, o kabindeki sunucular\u0131n ba\u011fland\u0131\u011f\u0131 ilk switch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Klasik \u00dc\u00e7 Katman ve Spine-Leaf Mimarisi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kurumsal a\u011flarda uzun s\u00fcre <strong>eri\u015fim (access) \u2013 da\u011f\u0131t\u0131m (distribution) \u2013 \u00e7ekirdek (core)<\/strong> \u015feklinde \u00fc\u00e7 katmanl\u0131 yap\u0131 kullan\u0131ld\u0131. Bu yap\u0131, trafi\u011fin \u00e7o\u011funun kullan\u0131c\u0131lardan internete (kuzey-g\u00fcney) akt\u0131\u011f\u0131 a\u011flar i\u00e7in tasarlanm\u0131\u015ft\u0131. Veri merkezlerinde ise trafi\u011fin b\u00fcy\u00fck k\u0131sm\u0131 sunucular aras\u0131nda (do\u011fu-bat\u0131) akar: uygulama sunucusu veritaban\u0131na, sanal makineler depolamaya ba\u011flan\u0131r. Bu y\u00fczden veri merkezlerinde <strong>spine-leaf<\/strong> mimarisi yayg\u0131nla\u015ft\u0131:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Leaf (yaprak) switch&#8217;ler:<\/strong> Genellikle kabinlerdeki ToR switch&#8217;lerdir; sunucular bunlara ba\u011flan\u0131r.<\/li>\n<li><strong>Spine (omurga) switch&#8217;ler:<\/strong> Her leaf, her spine&#8217;a ba\u011flan\u0131r; spine&#8217;lar birbirine ve sunuculara ba\u011flanmaz.<\/li>\n<li><strong>Sonu\u00e7:<\/strong> Farkl\u0131 kabinlerdeki iki sunucu aras\u0131ndaki yol her zaman leaf \u2192 spine \u2192 leaf \u015feklindedir; gecikme \u00f6ng\u00f6r\u00fclebilirdir. Trafik birden fazla spine&#8217;a e\u015fit maliyetli yollarla (ECMP) da\u011f\u0131t\u0131l\u0131r, bir spine ar\u0131zalansa da a\u011f \u00e7al\u0131\u015fmaya devam eder.<\/li>\n<li><strong>B\u00fcy\u00fcme:<\/strong> Yeni kabin i\u00e7in leaf, daha fazla kapasite i\u00e7in spine eklenir.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Datacenter Switch Se\u00e7erken Nelere Bak\u0131l\u0131r?<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Port say\u0131s\u0131 ve h\u0131z\u0131:<\/strong> Kabindeki sunucu say\u0131s\u0131 \u00d7 ba\u011flant\u0131 h\u0131z\u0131 ve gelecek b\u00fcy\u00fcme.<\/li>\n<li><strong>Uplink kapasitesi ve oversubscription:<\/strong> Sunucu portlar\u0131n\u0131n toplam h\u0131z\u0131n\u0131n uplink&#8217;lere oran\u0131 (\u00f6r. 3:1). Oran d\u00fc\u015ft\u00fck\u00e7e t\u0131kanma riski azal\u0131r.<\/li>\n<li><strong>Yedeklilik:<\/strong> \u00c7ift g\u00fc\u00e7 kayna\u011f\u0131, \u00e7ift ToR ve sunucular\u0131n iki switch&#8217;e ba\u011flanabilmesi (MLAG, EVPN multihoming gibi).<\/li>\n<li><strong>Yaz\u0131l\u0131m \u00f6zellikleri:<\/strong> VLAN, VXLAN\/EVPN, BGP gibi protokol deste\u011fi ve otomasyon (API, Ansible) imk\u00e2n\u0131.<\/li>\n<li><strong>Hava ak\u0131\u015f\u0131 ve g\u00fc\u00e7:<\/strong> Kabin d\u00fczenine uygun hava ak\u0131\u015f\u0131 y\u00f6n\u00fc ve g\u00fc\u00e7 t\u00fcketimi.<\/li>\n<li><strong>Lisans ve destek:<\/strong> Baz\u0131 \u00f6zellikler ek lisans gerektirir; \u00fcreticinin destek s\u00fcresini kontrol edin.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6rnek bir \u00fcr\u00fcn ailesini incelemek isterseniz <a href=\"https:\/\/sunucun.com.tr\/blog\/juniper-switch-urun-ailesi\/\">Juniper switch \u00fcr\u00fcn ailesi<\/a> ve <a href=\"https:\/\/sunucun.com.tr\/blog\/juniper-qfx5100-icin-vlan-yapilandirmasi\/\">Juniper QFX5100 VLAN yap\u0131land\u0131rmas\u0131<\/a> yaz\u0131lar\u0131m\u0131za bakabilirsiniz.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">ToR switch ile leaf switch ayn\u0131 \u015fey mi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c7o\u011fu zaman evet. ToR fiziksel konumu (kabinin tepesi), leaf ise spine-leaf mimarisindeki rol\u00fc anlat\u0131r. Kabin \u00fcst\u00fcndeki switch genellikle ayn\u0131 zamanda leaf switch&#8217;tir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bir kabine neden iki ToR switch konur?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yedeklilik i\u00e7in. Sunucular iki switch&#8217;e birer kabloyla ba\u011flan\u0131r; switch&#8217;lerden biri ar\u0131zaland\u0131\u011f\u0131nda veya g\u00fcncellendi\u011finde sunucular di\u011fer switch \u00fczerinden \u00e7al\u0131\u015fmaya devam eder.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kendi sunucum i\u00e7in datacenter switch almam gerekir mi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Veri merkezinde bar\u0131nd\u0131r\u0131lan bir <a href=\"https:\/\/sunucun.com.tr\/vds-sunucu\">VDS<\/a> veya <a href=\"https:\/\/sunucun.com.tr\/fiziksel-sunucu\">fiziksel sunucu<\/a> kiralad\u0131\u011f\u0131n\u0131zda a\u011f altyap\u0131s\u0131 sa\u011flay\u0131c\u0131 taraf\u0131ndan kurulur ve y\u00f6netilir. Kendi donan\u0131m\u0131n\u0131z\u0131 veri merkezine koyuyorsan\u0131z <a href=\"https:\/\/sunucun.com.tr\/sunucu-barindirma\">sunucu bar\u0131nd\u0131rma<\/a> hizmetinde a\u011f ba\u011flant\u0131s\u0131 da sa\u011flan\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sonu\u00e7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Datacenter switch&#8217;ler veri merkezinin sinir sistemidir. Kabin d\u00fczeyinde ToR switch&#8217;ler sunucular\u0131 ba\u011flar, spine-leaf mimarisi de bu switch&#8217;leri \u00f6ng\u00f6r\u00fclebilir gecikme ve kolay b\u00fcy\u00fcme sa\u011flayacak \u015fekilde birle\u015ftirir. A\u011f kavramlar\u0131na yeniyseniz <a href=\"https:\/\/sunucun.com.tr\/blog\/network-nedir\/\">network nedir<\/a> yaz\u0131m\u0131zla ba\u015flayabilirsiniz.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>K\u0131sa cevap: Datacenter switch, veri merkezindeki sunucular\u0131, depolama sistemlerini ve di\u011fer a\u011f cihazlar\u0131n\u0131 birbirine ve internete ba\u011flayan, y\u00fcksek port yo\u011funluklu ve d\u00fc\u015f\u00fck gecikmeli a\u011f anahtar\u0131d\u0131r. En yayg\u0131n t\u00fcr\u00fc ToR (Top of Rack) switch&#8216;tir: her kabinin en \u00fcst\u00fcne konur ve o kabindeki sunucular do\u011frudan ona ba\u011flan\u0131r. ToR switch&#8217;ler de g\u00fcn\u00fcm\u00fcz veri merkezlerinde \u00e7o\u011funlukla spine-leaf mimarisiyle birbirine&hellip;<\/p>\n","protected":false},"author":1,"featured_media":19190,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[1522],"tags":[],"class_list":["post-8970","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-isletim-sistemleri"],"_links":{"self":[{"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/posts\/8970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/comments?post=8970"}],"version-history":[{"count":2,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/posts\/8970\/revisions"}],"predecessor-version":[{"id":19193,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/posts\/8970\/revisions\/19193"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/media\/19190"}],"wp:attachment":[{"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/media?parent=8970"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/categories?post=8970"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sunucun.com.tr\/blog\/wp-json\/wp\/v2\/tags?post=8970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}